SikaGrout 212-11/214-11 Bookmark and Share

Special Festures:

High  strength,  adjustable  consistency

No  bleeding

Non toxic, non corrosive

Ready to use, requires only the addition of water

SikaGrout  212-11  and  SikaGrout  214-11  are  non-shrink,  self-levelling, pre-mixed  cementitious  grouting  mortars  with  extending  working  time  to suit  local  ambient  temperature.

 

SikaGrout  212-11  and  SikaGrout  214-11  are  suitable  for  the  following  grouting  works:

 

Machine  foundations

Rails  beds

Columns  in  precast  construction

Anchor  bolts

Bridge  bearings

Cavities

Gaps

Recesses

High  strength  repair

 

Advantages:

Excellent  flowability

Good  dimensional  stability

High  strength,  adjustable  consistency

No  bleeding

Non toxic, non corrosive

Ready to use, requires only the addition of water

Impact  and  vibration  resistant

Can  be  placed  with  suitable  grout  pump

 

Product Da Ta

Powder / Concrete grey

 

25 kg bag

 

Dry,  cool,  shaded  place

 

Min.  6  months  if   stored  properly  in  unopened,  original  packaging

 

Technical  Data

 

~ 1.60   kg/ltr    (bulk density of powder)

~ 2.20   kg/ltr    (density of fresh mortar)

 

SikaGrout  :  water    =  1  :    0.150      (parts by weight)

 

~ 3.75 litres of clean water per   25 kg bag

 

1 bag yields approx. 13.10   litres of mortar

3

Approx. 76 bags required for 1 (one) m   of mortar

 

o

Minimum   10   C

 

o

Maximum 40   C

 

SikaGrout 212-11:       8 mm

SikaGrout 214-11:    10 mm

Application:

Concrete  surfaces  should  be  clean,  sound  and  free  from  oil,  grease, laitance  and  loose  particles.

Metal  surfaces  (iron  and  steel)  should  be  free  from  scale,  rust,  oil  and grease.

Absorbent substrates must be saturated thoroughly, but no standing water.

 

Powder  should  be  added  to  the  pre-gauged  water  to  suit  the  desired  consistency.

 

Mix  mechanically  for  at  least  3  minutes  with  a  low  speed  electric  drill  (max. 500 r.p.m.) with a disc agitator attached, until a smooth consistency is  achieved.

Mixing equipment such as two arms, forced action basket/pan type mixer  can  also  be  used.

Pour mortar after mixing. Ensure that air entrapped into the grout is allowed

to escape. When carrying out base plate grouting, ensure sufficient head of

pressure is maintained to keep mortar flow uninterrupted. Make sure that

necessary form work is firmly in place and watertight. To achieve optimum

expansion result, apply mortar as quickly as possible (preferably within 15

minutes after mixing)

 

Grouting of machine beds

 

Pre-wet thoroughly, no standing water in bolt holes. If possible, grout anchor

first, and the mortar bed in the second operation. Ensure continuous flow of

mortar.

 

Grouting base plate

 

Prewetting for approx. 24 hours, no standing water. Maintain constant hydro-

static pressure to continuous flow. Use steel rods or chain to make sure that

all cavities are filled. Make sure that entrapped air can escape easily.

 

Grouting of large cavities / large volume

 

Depending on the volume to be filled and thickness of gap, large aggregates, e.g. 4-8 mm, 8-16 mm or 16-32 mm may be added to the SikaGrout 214-11 at a ratio of between 50-100% by weight of SikaGrout 214-11 powder. Round aggregates are more suitable than crushed ones.

 

As a rule of thumb, minimum thickness of gap to be grouted shall be 3 times max. grain size diameter of aggregate.

For  grouting  large  section  thicker  than  60-mm,  addition  of  large  aggre- gate  and/or  use  of  cold  water  will  minimize  temperature  rise  generated during  early  hardening  period.

 

Keep visible, free mortar surface as small as possible and protect it from premature drying out by standard curing practice (keep moist, cover with wet  hessian,  use  of  curing  compound  e.g. Antisol  E)

 

Clean  all  tools  and  equipment  with  water  immediately  after  use.  Hard- ened  mortar  can  only  be  removed  mechanically.

 

o                                                                                            o

Minimum application temperature is 10 C. At temperature lower than 20 C setting  time  and  strength  gain  will  be  slower.

Normal  curing  practice  should  be  observed  for  at  least  3  days  wherever mortar  is  exposed.

In  case  of  grouting  large  cavities/volume,  SikaGrout  214-11  is  the  most

>> Sản phẩm cùng loại

Waterbars Yellow Met

220x220_otc_2471553jpg

Giá bán : 195.000

Waterbars Grey

chatchenkhechobetongsikahydrotitecjtype_1268377373

Giá bán : Call

SikaTop ® 121

f7c3fb92f466f38f57cb334f27a7288e

Giá bán : Call

SikaTop Seal 107

sikatopseal107_1268147420pjpeg

Giá bán : Call

SikaSwell ® S-2

sk_Topseal_107

Giá bán : Call

Sikasil ® E

885626ceb709362a7fb0b52c38669a7d

Giá bán : Call

1 2 3 4 5 ...>>